renogy rover lifepo4 settings

It may not display this or other websites correctly. I have configured the following, but I am not sure this is correct. Soft package cell refers to the use of aluminum-plastic film as the packaging material of the cell. How many batteries can I connect to at most? Equalize Charge Interval 185 (Note this value cannot be 0 because controller can get stuck in boost mode) I found this out by trial and error. Use Energy Pal to have professionals install an offgrid system! This was all new this year. The Rover LI settings are to aggressive for Lifepo4 Batteries. JavaScript is disabled. 50% more heat dissipation area will maximize the safety of your off-grid use. Renogy 100 Ah LifePo4 self heating battery and Noco genius 5x1 battery charger along with a battery monitor, the BT1 bluetooth antennae, and various other doo dads. Just ordered a 40a circuit breaker to go between the charge controller and batteries plus the Blue Sea 5191 terminal block and 200a fuse today. I sure hope so. charge volt (disabled) 14.4. boost charge volt 14.4 (set to 300 minutes) float charge volt 14.4. You are using an out of date browser. Isn't setting the ECI to 185 for lithium batteries equivalent to eliminating it? " But at the same time I have been told that that float voltage will kill the batteries. For a better experience, please enable JavaScript in your browser before proceeding. Over volt protection if continually applied by the BMS may. 3 offers from $184.99. Not up for DIY? Your Experience with LiFePO4 Deep Cycle Batteries? My battery charges at 14.6v @80amps. Grid Interactive and Inspection Approved 48V System, Solar Friendly Heat Pump Air Conditioners. Is It Time To Replace Your RV Window Seals? Note: This feature currently requires accessing the site using the built-in Safari browser. I used Will's video (. So perhaps you can use those as a guide. 12V 100Ah Smart Lithium Iron Phosphate Battery. Right now I am switching from an FLA battery to a LiFePo4 battery. Programming Parameters RENOGY RoVer 40 amp Solar Charger Controller Nominal battery voltage normally 13.5 - 13.8v, Unless Im confused, charge voltage not the same as battery voltage. It probably did go to Boost mode (for 60 minutes) but I didnt see it. Add to Cart Suggested Products REGO 12V 60A MPPT Solar Charge Controller with Anderson terminals Compare CAD $459.99 CAD $413.99 Choose Options Do You Need a Special Charge Controller for LiFePO4 Batteries #8. Could you please post the full set of instructions for LiFePO4 here so that others can find it quickly in this thread? Renogy mentions 14.4v Over voltage disconnect voltage 16.0v Charging limit voltage 16.0v I see it in "float" a lot since I sometimes do not use my shop. By accepting all cookies, you agree to our use of cookies to deliver and maintain our services and site, improve the quality of Reddit, personalize Reddit content and advertising, and measure the effectiveness of advertising. (self built) High volt disc: 14.7. I changed the float voltage to 13.5 (was 13.8) and the Rover switched to MPPT charge mode. 3. 20 Amp controller. The Renogy 20A Rover MPPT Charge Controller is the most efficient type of charge controller. Awesome. Agreed. Renogy downloads allows you to view and download quick guides, data sheets, user manuals, and how-to videos of Renogy products. Terms and Conditions of $1 Renogy ONE Lightning Deal: Connect with other users and explore their real-life experiences, w/Renogy ONE Core & BT (Early Bird Offer), Decrease Quantity of 12V 100Ah Smart Lithium Iron Phosphate Battery, Increase Quantity of 12V 100Ah Smart Lithium Iron Phosphate Battery. The job of the solar charge controller is to regulate the power going from the solar panels to the batteries. All rights reserved. The next-level pouch cells surpass severe high temperature and puncture tests to avoid fire or explosion. View and download quick guides, data sheets, user manuals, and how-to videos of Renogy products. Amazing they are so Lazy as to not change the Parameters, how many People Will cook their battery's not knowing this?- Thanks Guys just Spent two hours trying to figure this out. That wont charge a battleborn. Reddit, Inc. 2023. 16 Dec 5, 2019 #1 I received the charging parameters from Renogy for me to enter into my MT50. How to Program Charge Controller for Lithium Batteries (MPPT v PWM I am using the settings that SolarShed suggested. More questions about your off-grid power system? It may not display this or other websites correctly. Will go with the 40A for my 600 Watt system to save $$ as it's a big jump to the 60A. Follow along with the video below to see how to install our site as a web app on your home screen. DIY Off Grid Solar Charge Controllers - DIY Solar Power - Made Easy! Can anyone help me with the best settings? Can anyone help me with the best settings? charge volt (disabled) 14.4. boost charge volt 14.4 (set to 300 minutes) float charge volt 14.4. boost char return volt 13.6. Ugh. In these rare cases the user will need to activate the battery using an external device that has lithium battery activation feature. LiFePo4 settings on Progressive Dynamics Converter - iRV2 Renogy LiFePO4 Compatible with Commander 60A MPPT Need Renogy Rover 40a settings for 12v LIFEPO4. Free Shipping Reliable Warranty Secure Payment The Renogy 40A Rover MPPT Charge Controller is the most efficient type of charge controller. The manual doesn't mention the ( USR ) icon that must be selected in order be able. is it from overcharging or undercharging that it enters protective mode? That isn't the charge voltage that they are referring to. I think it'll come down to how much of a bear it is to set up a custom profile. Our battery is capable of 4000 cycles of perfect charge and discharge, after which the efficiency of the battery will drop to 80% of the factory performance, but it is still very good for your use. Here's the problem. Currently, there are a few battery brands on the market using pre-used battery cores, these have a negative impact on the batterys life span and present safety risks. This seems rather strange. According to the manual by default the lithium setting is 12.8 volts. Are there settings I should change in the controller for this specific battery? I have 2x 100 AH 12v LiFePo4. Help? All rights reserved. Equalize Charge Interval 185 (Note this value cannot be 0 because controller can get stuck in boost mode). Here's How To Get Internet While Traveling With A Cell Ph Are You Replacing Your RV Anode Rod Often Enough? Learn solar technology and its benefits as well as how to start your solar journey with Renogy products. Renogy Rover 60 manual link. Overvoltage protection is a part of controlling the charging process. Time. Check out page 32 of the Rover 60 manual for how the charge parameters are set for Lithium. Create an account with us and you'll be able to: Exclusive rewards and exciting adventures all start here Firstly, our batteries use the most up to date pouch cell technology. They dont say what happens after the battery bank reaches 14.6v. I wrote that a bit wrong above and past the time I can edit it. What are Renogy batterys greatest advantages. It's correct what Renogy say. I received the charging parameters from Renogy for me to enter into my MT50. JavaScript is disabled. Thanks for the info, I get no heat from the 2 awg wire so that's good for me. With up to 99% tracking efficiency, the Rover ensures maximum power point solar charging that gets more energy to your battery bank. Set your the values as for a12v system and change the battery voltage type to 24 volts. How to keep a Lithium-iron Phosphate battery healthy at low temperatures? Please take the time to register and you will gain a lot of great new features including; the ability to participate in discussions, network with other RV owners, see fewer ads, upload photographs, create an RV blog, send private messages and so much, much more! (self built) High volt disc: 14.7 Charge limit volt: 14.6 equ. Reddit and its partners use cookies and similar technologies to provide you with a better experience. Also keep your float voltage down around 13.6-13.8V. Join the #1 RV Forum Today - It's Totally Free! If I tried the user setting maybe it will allow me to use advanced setting. New Renogy LiFePo4 battery, Rover "E4" error code? - Fiberglass RV Yes! Chin 12v 300ah with Renogy Rover 40amp mppt. I have configured the following, but I am not sure this is correct. You must log in or register to reply here. Yes, I did read a few times in the manual that the battery needs to be connected first. Help with settings for renogy commander 40a and mt50 for chins 1000ah lifepo4. Rover 40 Amp MPPT Solar Charge Controller with Bluetooth The thing you might not need 'special' controllers just because you are using lithium batteries. And it is best to use flexible busbars or dedicated cables to connect batteries together. Nominal battery voltage normally 13.5 - 13.8v. Beginner Friendly "Plug-n-Play" Lithium Batteries. Thanks for this. [Help] Need Renogy Rover 40a LiFePo4 settings : r/solar I dont think I can see Renogy LI parameters . O.K. Their product does not have any features for boost or float in Lithium mode. ONLY connect batteries of the same manufacturer and model in parallel. For 24 volt systems double values and for 48 volt systems multiply by 4. Overcharging batteries will at the least significantly reduce battery life and at worst damage the batteries to the point that they are unusable. Solar Equipment Reviews and Technical Support. Buy in monthly payments with Affirm on orders over $50. How do you get past this? You must log in or register to reply here. Not up for DIY? You are using an out of date browser. Renogy LifePO4 Smart Battery Charge Parameters / MT50 You are going to have to adjust the bulk setting to 14.4 volts to charge the battleborn. PDF User Guideline Roger Sayers 354 subscribers Subscribe 44K views 3 years ago Explanation of how to set up the charge parameters. And mine says bulk charging but battery is 100%. DO NOT connect batteries with different chemistries. You must log in or register to reply here. You are going to have to adjust the bulk setting to 14.4 volts to charge the battleborn. I have 2x 100 AH 12v LiFePo4. JavaScript is disabled. https://preview.redd.it/9z8gjjve1q091.jpg?width=385&format=pjpg&auto=webp&s=d4a087b1d55a8f4dd6ca3fe533aa31c8a1277513, two Miady 12V 20Ah batteries connected in parallel. My battery charges at 14.6v @80amps. Not up for DIY? Adjust the parameters so it looks like the following. Incredibly advanced BMS provides over 20 protections designed to allow a peak current of 150A to pass through, deliver up to 1C charging and 1.3C discharging during an emergency. You are using an out of date browser. My understanding is the Renogy Rover SCCs are intended to be directly compatible with the Renogy LiFePO4 batteries. 6140 Thornbury Ct SE, Olympia, WA, 98513, USA, Another Renogy Rover 60A MPPT issue: 24V settings, Renogy 60A MPPT with BigBattery 24V Mule Settings, Renogy Rover 40A settings for Ampere Time 200Ah Li. Victron mppt 75/15 bluetooth 0 amps 0 watts with lifepo4 12v battery. I have been calling Renogy support but they've "dropped" my call while transferring me to a technician 3 times now so I think I'm on my own for the time being. Replacing a Schumacher OEM Converter for a Progressive Dynamics 4 stage converter, Extension cord info for Progressive Dynamics pwr converter, Progressive Dynamics PD 734 converter upgrade, Buying a Progressive Dynamics 9145 converter, Currently Active Users Viewing This Thread: 1. My understanding is the Renogy Rover SCCs are intended to be directly compatible with the Renogy LiFePO4 batteries. Is your Rover connected to a 12V battery? The Rover will autosense the voltage and select the proper multiplier . I went into the parameters after setting it up for 24V and they seem to be stuck on the values for a 12V battery. Finally, we provide a 5 year industry leading warranty on all Renogy batteries. For a better experience, please enable JavaScript in your browser before proceeding. https://www.amazon.com/Victron-SmartShunt-500AMP-Bluetooth-Battery/dp/B0856PHNLX, https://www.amazon.com/Victron-BMV-712-Battery-Monitor-Black/dp/B084M2XYK4, Renogy 60A MPPT with BigBattery 24V Mule Settings, Couple of newbie questions (Renogy Rover MPPT and Bluetooth, Renogy LiFePO4), renogy 40a mppt charge controller shuts down when it reaches boost voltage. Renogy 12V 100Ah Smart Lithium Iron Phosphate Battery The Renogy Smart Lithium Iron Phosphate Battery enables auto-balance among parallel connections and provides more flexibility for battery connection. I don't know about the Commander but some of the SCCs make it less than easy to configure. Our battery is connected with a battery switch, which can turn off the battery and the BMS system with one key when the battery is not needed to work, reducing the self-consumption of the battery, making it safer to store, and protecting the battery life. When safety problems occur, gas and heat can be released through the sealing mouth to avoid the further triggering reaction. Mission Statement: Supporting thoughtful exchange of knowledge, values and experience among RV enthusiasts. Reddit, Inc. 2023. I recently upgraded my 200Ah AGM deep cycle batteries to Ampere Time 200Ah, following Will's recommendation on his forum, as my AGM batteries are now 4 years old and not likely to last much longer in my desert climate where temps often exceed 104 F. Thank you all for your detailed and helpful advice. Frequently bought together. Amper time may not have completely balanced cells so high cell protection may stop the charge process. I was reading in another thread that this Rover Li controller isn't actually configured for LiFePO4, which I found a little confusing. Follow along with the video below to see how to install our site as a web app on your home screen. AStravelers Well-known member Joined Nov 14, 2016 Posts 1,590 Location San Antonio, TX Make sure you can program the charge voltage to the batteries so voltage stays below 14.2V. Compared with the metal shell of the same capacity, the soft pack battery is light in weight and has good cycling performance. Secure Payment. Li 20 Amp Rover MPPT Solar Charge Controller | Renogy Solar Ps Ive only set the absorption time to 10 minutes for the porpoise of the test, in reality the lower the voltage being used the longer the absorption will take to get to a required Soc. It won't let me step up the numbers on the charger and will not accept them when entered via the app with the BT-1 interface. confirmedProgressive tech support is saying the converter charge voltage is constant 14.6V. Use Energy Pal to have professionals install an offgrid system! Reddit, Inc. 2023. Does the charger shut off? Need Renogy Rover 40a settings for 12v LIFEPO4 : r/SolarDIY I was reading in another thread that this Rover Li controller isn't actually configured for LiFePO4, . Renogy Rover 40 MPPT User Settings not Accepted for 24V System Renogy Rover Solar Charge Controllers only have settings for 12 volt systems. So perhaps you can use those as a guide. No matter where you fit in you'll find that iRV2 is a great community to join. My camper has a Progresssive Dynamics PD4500 converter/charger and a Renogy Rover 40A solar controller. By rejecting non-essential cookies, Reddit may still use certain cookies to ensure the proper functionality of our platform. If being used daily and solar is charging/ floating it would be foolish to run off batteries when solar could carry the loads. Do you need advice on what products to buy? I have 2x 100 AH 12v LiFePo4. Would like to know the best parameters setting in order to achieve the optimum life cycles for rechargeable lithium iron battery banks, Programming a Tracer charge controller for LiFePo batteries. +. 12V 100Ah Batteries,Caravan Leisure Battery,Lithium Battery|Renogy UK I hope you laughed hard, loud and long when Renogy told you that. What is ideal about only the charger providing overvoltage protection, and not the BMS too? #1 I recently upgraded my 200Ah AGM deep cycle batteries to Ampere Time 200Ah, following Will's recommendation on his forum, as my AGM batteries are now 4 years old and not likely to last much longer in my desert climate where temps often exceed 104 F. Any help would be appreciated. Second question if you look at specs posted below, I also do not understand why the renogy mppt controller even when set to lithium setting, has default a charge limit voltage set to 15.5 volts, where as most of the other settings are automatically set to 14.4 in its parameters. When does the charger turn back on? Discover the steps to DIY solar: assess energy needs, select panels, and generate clean, renewable energy for your project or home. For more information, please see our The equalize time is set to 0 mins. TL;DR: battery manufacturer specs don't match Li profile on Charge controller, and some specs don't transfer between them (like, my CC is trying to "boost . My LiFePo4 battery seldom exceeds 13.8 v, when my bm shows 100%SOC. Unless Im confused, charge voltage not the same as battery voltage. It briefly . Thats when charging stops. Best Charge Controller LiFePO4 Battery Settings Go to the settings in your charge controller. Tell Renogy you want the 20% off discount they were giving on Black Friday for your troubles. Here are a couple of screenshots. Split charge relay capable of charging 360Ah Battery Bank? I have configured the following, but I am not sure this is correct. (self built), boost charge volt 14.4 (set to 300 minutes), Scan this QR code to download the app now. Find out featuring tutorials, blog posts, videos, and more to keep you up-to-date on the latest solar news and information. Use Energy Pal to have professionals install an offgrid system! I set up the Renogy BT app and programmed these setting for my LiFePO4 bank. Find the answers to the most frequently asked questions here, and we're always here to help. Beat The Heat In Your RV This Summer: 10 Ways To S Power Outages At RV Parks: What You Need To Know, Camper Smarts - Resources for Smart RVers, Powered by vBulletin Version 3.8.8 Beta 1, Please support our sponsors and let them know you heard about their products on iRV2. That is the nominal voltage of a LiFePO4 battery with four 3.2V cells in series. Register today and take advantage of membership benefits. That charger in the LI setting will give a charge voltage of 14.6v and the charge wizard is disabled. That wont charge a battleborn. Hi all, I have the same issue I can't change any of the 24V settings above 17, any help would be appreciate. JavaScript is disabled. Keep the connection tight by using the appropriate number of washers to allow for as much as possible thread engagement between the terminal, cable lugs, and busbars, without bottoming out the terminal bolt. My equalize, boost, float charge voltage values are exactly the same (13.8v). Whenever the Noco 5x1 starts charging, or stops charging, The Rover charge controller senses a load short circuit and cuts out power automatically. If you live a completely off-grid life, calculated at the rate of a full charge and discharge per day, you will be able to use it for more than 10 years. The battery cell not only passes the UL1642 but also offers over ten years of lifespan with more than 4,000 cycles (80% DOD). click here to purchase. With up to 99% tracking efficiency, the Rover ensures maximum power point solar charging that gets more energy to your battery bank. RV park life, is it affordable for low income? If you buy this Renogy Lithium-iron Phosphate battery without a self-heating function, please pay attention to timely charging it at the appropriate temperature to prevent the battery from overdischarging. The 8 guage is less than 2 feet and I did find a little heat when the You must log in or register to reply here. https://www.autoevolution.com/news/the-new-tesla-recommendation-for-the-cars-with-lfp-batteries-changes-everything-you-know-177815.html, Fully charged battery depletes at night with no loads attached, Sol Ark 12K Low SOC - Not Switching to Grid - need some advice pls, Renogy 60A MPPT with BigBattery 24V Mule Settings, Renogy Wanderer 10amp Charge controller charging behavior on lithium setting. What is the specific soft package cell mentioned just now? Occasional Mobile Solar ? Note: DO NOT connect batteries in series. Li 40 Amp Rover MPPT Solar Charge Controller | Renogy Solar Yes you should use the USR settings. 7. Easily connect multiple batteries in parallelup to 8with the auto-balancing function, improving the average charging efficiency for your batteries in the long term. How to know when your Lifepo house battery is charged. The rover has -- for boost duration on Li. If youre searching for a deep cycle battery for caravan, cabin, or marine use, this lightweight, auto-balanced, ultra-safe, long-cycle-life lithium-ion battery is the perfect solution for you! Does anyone have suggestions for the most optimal settings for the Renogy Rover Li controller paired with these LiFePO4 batteries? Contact our professional service team for help via phone, livechat, or email. "With our Li batteries, we would recommend setting the charging voltage to 14.4 0.2V, the float voltage must be set to the same voltage as our batteries do not require a floating stage. Charge limit volt: 14.6. equ. Safe charging requires battery temperatures between 32F and 131F (0C and 55C). Best of all it's totally FREE! On page 19 of the manual looking through the steps it give eq. As of now since its dark this is all I can see . It's cable reimagined No DVR space limits.

Trinity College Administration, Articles R